Verilink WANsuite 5130 (34-00298.L) Product Manual User Manual

Page 67

Advertising
background image

W e b S e r v e r I n t e r f a c e

3-35

Message Size

Maximum number of characters to buffer before sending a frame.

Values: 0

1024

Default: 256

Idle Character Delay

Maximum number of idle character time to wait before sending a frame.

Values: 0

65535

Default: 10

Input Terminator

Decimal value of the character that terminates a message before sending a
frame.

Values: 0

255

Default: 0

Data Direction

Data direction that the port will support. If set to “Input,” the port will only
accept incoming data and will not transmit data. If set to “Output,” the port
will ignore any incoming data. If set to “Both,” the port will process all data.

Values: Input, Output, Both
Default: Both

SCADA Loopback

Determines if and where SCADA will loopback received data.

Values: None, Loopback to Network, Loopback to Port
Default: None

The table below these parameters displays the SCADA statistics.

The SCADA Details screen provides the following user-activated buttons:

Figure 3.28

SCADA Device List Screen

Select the appropriate numbered link under the “Device column to access the
SCADA Device Details screen(Figure 3.29) where you can map SCADA
devices to endpoints.

Button

Function

Submit

Sets any values that have been changed.

SCADA Device List

Displays a table that shows the mapping between
SCADA devices and endpoints (Figure 3.28).

Clear SCADA Statistics

Clears all SCADA statistics.

Advertising