Dtr alarm, Reset timer, Reset alarms – Verilink WANsuite 5130 (34-00298.L) Product Manual User Manual

Page 226: Performance menu, Dtr alarm -8 reset timer -8 reset alarms -8, Performance menu -8

Advertising
background image

5-8

W A N s u i t e 5 1 6 0 / 5 1 3 0

DTR Alarm

Read-only field that displays the current DTR Alarm status. This register
shows “OK” when no alarms are detected, and shows “ALRMD” when the
unit alarms a loss of DTR.

Reset Timer

This field is the contiguous number of seconds that an alarm parameter must
be clear before the alarm is reset. Applicable values range from 000 through
899. A value of “000” means that the alarm never resets. Press

SELECT

to

change this threshold.

Reset Alarms

This option clears the alarm counts. To reset the alarms, press the

SCROLL

button to bring up the “Yes” option, and then press the

SELECT

button.

Performance Menu

The PERFORMANCE menu displays a history of the network error
parameters that are continuously monitored. This register lets you view the
24-hour performance totals from the unit. Only the 5160’s Network 1
Performance menu is shown below in Figure 5.10 because the parameters are
the same for the WANsuite 5160 Network 1 and Network 2 menus and also
for the Network menu in the WANsuite 5130.

Figure 5.10

Performance Menu Tree

The parameters found on this menu are the same as on the Alarms menu tree,
except for the three additional parameters defined below.

Net 1 24-hour

Perf

(read-only fields)

Rx
ES

SES

LOSS

OOFS
BPVS

CSS

RAS

AISS

UAS

CRCES

BES

LOFC

Net 1

Performance

Advertising