W e b S e r v e r I n t e r f a c e

3-31

FrameStart Auto Diagnostic mode should be left set to “Yes” unless the frame
relay connection has more that 128 DLCIs, or if there is a very high traffic
rate on a constant basis.

Values: No, Yes
Default: Yes

NOTICE:

If either side of the Frame Relay connection goes down, you will be
unable to remotely access any connected units.

FrameStart Auto

Discovery

When this parameter is set to “Yes,” the unit will send FrameStart discovery
and delay frames to each DLCI it learns as soon as the DLCIs are set active.
This is required to calculate round trip delay as well as to discover remote
WANsuite 5160/5130/FST/FSD units. This parameter should be set to “Yes”
only on network services that have a WANsuite 5160/5130/FST/FSD at the
far end of the frame relay connection. Also if set to “Yes,” the unit will gather
SLA parameters such as frame and data delivery ratio as defined in the Frame
Relay Forum Implementation, FRF.13. Those gathered statistics are then
displayed on the DLCI Statistics screen as shown on page 3-49.

Values: No, Yes
Default: No

Round Trip Delay Size

(bytes)

Specifies the frame size (in bytes) of packets making the round-trip.

Round Trip Delay Rate

(secs)

Specifies the rate (in seconds) at which Round Trip Delay packets are sent.

Status and Alarms Table

The table displayed at the bottom of the Frame Relay Service Details screen
reports on the status and condition of LMI parameters and on Receive/
Transmit alarms and thresholds. Alarm threshold levels may be changed by
entering a new threshold value in the appropriate field of the table and
clicking the “Submit” button. Table fields are described below.

Active

Read-only field shows whether or not (Yes or No) an alarm is active.

LMI Type

Read-only status indicates ANSI, CCITT, LMI rev. 1, or Unknown.

FrameStart Status

Read-only status indicates Sourcing, Monitoring, or 0.

Rx Invalid Threshold

Number of invalid frames received during a 15-minute interval after which an
invalid alarm will be triggered. Default of “0” disables this alarm.

Rx Invalid Alarm

Status of this alarm indicates OK or Alarmed.

Tx Threshold

Number of bits per second sent during a 15-minute interval after which a Tx
alarm will be triggered. Default of 0 disables this alarm.