155 rmon event, 156 sfp temperature-threshold – PLANET WGSW-48040HP User Manual

Page 250

Advertising
background image

Command Guide of WGSW-48040HP

Switch# configure terminal

Switch (config)# rmon alarm 1 .1.3.6.1.2.1.2.2.1.10.15 50 absolute rising-threshold

1000 1 falling-threshold 520 1 falling

4.2.155 rmon event

Command:

rmon event <id: 1-65535> [ log ] [ trap <community> ] { [ description <description> ] }

rmon Remote Monitoring

event Configure an RMON event

<id: 1-65535> Event entry ID

description Specify a description of the event

<description> Event description

log Generate RMON log when the event fires

trap Generate SNMP trap when the event fires

<community> SNMP community string

Default:

None

Usage Guide:

To configure the Event of RMON

Example:

To configure the Event (below table) of RMON

Switch# configure terminal

Switch (config)# rmon event 1 log trap planet description error

4.2.156 sfp temperature-threshold

Command:

sfp temperature-threshold <0-100>

sfp temperature-threshold Set a lower high temperature threshold for the secondary

temperature alarm in degrees C.

<0-100> Specifies the new threshold temperature.

-250-

Advertising