Command Guide of WGSW-48040HP

clock summer-time <WORD> date <Monthstart: 1-12> <Daystart: 1-31> <Yearstart:

1-12> <Timestart: hh:mm > <Monthend: 1-12> <Dayend: 1-31> <Yearend: 1-12>

<Timeend: hh:mm > <Offset minutes: 1-1440 >

Default:

N/A

Usage Guide:

To set daylight saving.

Example:

To set daylight saving (Started time: Feb, 3. 2013 8:8AM, End time: Dec, 31. 2013 8:8AM, Offset time: 60 minutes).

Switch# configure terminal

Switch (config)# clock summer-time 1 date 2 3 2013 8:8 12 31 2013 8:8 60

4.2.24 clock timezone

Command:

clock timezone <WORD> <timezone: -23-23>

<WORD> name of time zone

Default:

0

Usage Guide:

To set timezone.

Example:

To set timezone (GMT -15) with profile 1.

Switch# configure terminal

Switch (config)# clock timezone 1 -15

4.2.25 default access-list rate-limiter

Command:

default access-list rate-limiter <RateLimiterId : 1-16>

<RateLimiterId : 1-16> Rate limiter ID