Scrub control register, Scrub control register -23, 5scrub control register – Motorola MVME172 User Manual

Page 313

Advertising
background image

Programming Model

http://www.mcg.mot.com/literature

5-23

5

Scrub Control Register

IDIS

When cleared, the Image DISable bit allows writes to the
upper MCECC control registers to duplicate the data to
the lower MCECC control registers. When IDIS is set, the
lower MCECC control registers are written separately by
the data on D00-D16. IDIS should only be set for test
purposes.

SBEIEN

Setting SBEIEN causes the logging of a single bit error to
create a true pulse on the INT signal pin.

SCRBEN This control bit enables the scrubber to operate. When

SCRBEN is set, the MCECC immediately performs a
scrub of the entire DRAM array. When the scrub is
complete, if software has cleared SCRBEN, then
scrubbing is not done again, until software sets the
SCRBEN bit. If software has not cleared the SCRBEN bit,
then when the amount of time indicated in the Scrub
Period (SBPD) Register expires, the MCECC scrubs the
DRAM array again. It continues to perform scrubs of the
entire DRAM array at the frequency indicated in the
SBPD Register. The scrubber does not start a new scrub
once the SCRBEN bit is cleared. The time between scrubs
is approximately two seconds times the value stored in the
SBPD Register. Note that power-up, local, or software
reset stops the scrubber.

SCRB

This status bit reflects the state of the scrubber. When the
scrubber is in the process of doing a scrub, this bit is set.
When the scrubber is between scrubs, this bit is cleared.

ADR/SIZ

1st $FFF43024/2nd $FFF43124 (8-bits)

BIT

31

30

29

28

27

26

25

24

NAME

RACODE

RADATA

HITDIS

SCRB SCRBEN 0

SBEIEN

IDIS

OPER

R/W

R/W

R/W

R

R/W

R

R/W

R/W

RESET

V PLS

0 PLS

V PLS

0 PLS 0 PLS

X

0 PLS

0 PLS