Memory Maps

http://www.mcg.mot.com/literature

1-37

1

Note

A bug in MVME172s that have MC2 chip revision $01 does
not allow the data registers to be accessed directly. You must
access them indirectly via the SCC chip. The software must
send a command to the control register that tells it that the
next thing read or written to the control register will go to the
data register. The following two macros are examples:

dev_addr

is a pointer to the base address of the SCC.

SCCR0

is the offset to the SCC control register #0.

#define READ_SCC(VAR_NAME)\

dev_addr[SCCR0] = 0x08;\

(VAR_NAME) = dev_addr[SCCR0]

#define WRITE_SCC(VAR_NAME)\

dev_addr[SCCR0] = 0x08;\

dev_addr[SCCR0] = (VAR_NAME)

Table 1-12. Z85230 SCC Register Addresses

SCC

Z85230 SCC Register

Address

SCC #1

(All MVME172

modules)

Port B Control

$FFF45001

Port B Data

$FFF45003

Port A Control

$FFF45005

Port A Data

$FFF45007

SCC #2

(200/300-Series

MVME172

only)

Port B Control

$FFF45801

Port B Data

$FFF45803

Port A Control

$FFF45805

Port A Data

$FFF45807