5-24

Computer Group Literature Center Web Site

MCECC

5

HITDIS

This bit controls a function that is not currently used in the
MCECC.

RADATA This bit controls a function that is not currently used in the

MCECC.

RACODE This bit controls a function that is not currently used in the

MCECC.

Scrub Period Register Bits 15-8

The Scrub Period Control Register controls how often a scrub of the entire
memory is performed if the SCRBEN bit is set in the Scrub Control
Register. The time between scrubs is approximately two seconds times the
value programmed into the Scrub Period Register. The scrub period can be
programmed from once every four seconds to once every 36 hours. This
register contains bits 15-8 of the Scrub Period Register.

Scrub Period Register Bits 7-0

This register contains bits 7-0 of the Scrub Period Register.

ADR/SIZ

1st $FFF43028/2nd $FFF43128 (8-bits)

BIT

31

30

29

28

27

26

25

24

NAME

SBPD15 SBPD14 SBPD13 SBPD12 SBPD11 SBPD10 SBPD9

SBPD8

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

RESET

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

ADR/SIZ

1st $FFF4302C/2nd $FFF4312C (8-bits)

BIT

31

30

29

28

27

26

25

24

NAME

SBPD7

SBPD67

SBPD5

SBPD4

SBPD3

SBPD2

SBPD1

SBPD0

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

RESET

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

Advertising