Spurious vector register, Timer frequency register – Motorola MVME2300 Series User Manual

Page 147

Advertising
background image

Raven Interrupt Controller

http://www.motorola.com/computer/literature

2-77

2

Spurious Vector Register

VECTOR Interrupt Vector. This vector is returned when the

Interrupt Acknowledge register is read during a spurious
vector fetch.

Timer Frequency Register

This register is used to report the frequency (in Hz) of the clock source for
the global timers. Following a reset, this register contains zero. For the
Raven implementation of MPIC on the MVME2300 series, this register
must be written with a value of $7DE290 (that is, 66/8 MHz or 8.25 MHz),
which corresponds to a 66MHz MPC bus.

Offset

$010E0

Bit

3
1

3
0

2
9

2
8

2
7

2
6

2
5

2
4

2
3

2
2

2
1

2
0

1
9

1
8

1
7

1
6

1
5

1
4

1
3

1
2

1
1

1
0 9 8 7 6 5 4 3 2 1 0

Name

VECTOR

Operation

R

R

R

R/W

Reset

$00

$00

$00

$FF

Offset

$010F0

Bit

3
1

3
0

2
9

2
8

2
7

2
6

2
5

2
4

2
3

2
2

2
1

2
0

1
9

1
8

1
7

1
6

1
5

1
4

1
3

1
2

1
1

1
0 9 8 7 6 5 4 3 2 1 0

Name

TIMER FREQUENCY

Operation

R/W

Reset

$00000000