Siemens Sinumerik 810T User Manual

Page 128

Advertising
background image

09.91

3 Operating Sequences

3.1.6 Setting data: ”R PARAMETERS”, ”SPINDLE”, ”AXIAL”, ”ANGLE OF ROTATION”, ”SCALE MODIFICAT.”

You can call up further screen forms with input
fields for other R parameters with the page
up/down keys ...

or

... you can call up an input screen form or a particular
R parameter using the alphanumeric keys and the
search key (”33” in example, ”R” need not be
entered).

Enter the value for the selected R parameter with the
numerical keys.
Subsequently, you can transfer the value into the
input field with the input key.

”SPINDLE” setting data

Using an input screen form, you can enter/modify the following spindle data via
”SETTING DATA”:

or

3

L

3

L

...

...

• • •

Designation

Standard

setting data

(delivery

state)

Maximum

input

value

1)

Input

unit

2)

Smoothing constant with threading

Progammed spindle speed limitation

Oriented spindle stop

Spindle speed limitation (absolute)

0

0

0

0

5

16000

359.9

16000

-

rev / min

1 / 10 degree

rev / min

1) The ”Maximum input value” is fixed in MD.
2) The ”Input unit” is fixed in MD:

you can also use 0.1 rev/min instead of rev/min.

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

3-27

SINUMERIK 810T, GA3 (BN)

Advertising