4 monitoring functions, 1 general, 2 diagnostics display on the crt – Siemens Sinumerik 810T User Manual

Page 242: 4monitoring functions

Advertising
background image

09.91

4 Monitoring Functions

4.1 General

4

Monitoring Functions

4.1

General

The control contains permanently active monitoring functions which detect faults in the NC, the
interface control and the machine at such an early stage that damage to the workpiece, tool or
machine are practically eliminated. If a fault occurs, first of all machining is interrupted and the
drives brought to a standstill, and then the reason for the fault is stored and displayed as an
alarm. At the same time the PLC is informed that an NC alarm is present.

Monitoring functions exist for the following areas:

Reading in

Format

Measuring circuit cables

Encoders and drives

Contour

Spindle speed

Enable signals

Voltage

Microprocessors

Serial interfaces

Transfer between NC and PLC

Voltage level of the back-up battery

System program memory

User program memory

4.2

Diagnostics display on the CRT

Messages from the monitoring system are displayed in the ”Alarm line” of the CRT display.
The ”Alarm line” is the second display line from the top.

Upper CRT display limit

Area for the
alarm no.
and further
identifiers

Area for the
alarm text

ALARM LINE

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

4-1

SINUMERIK 810T, GA3 (BN)

Advertising