11.90

6 Data Interfaces

6.4 Device connection data

Siemens page printer PT80

Cable Order No.:

6FC9 340-8C
RS232C (V.24 )
6FC9 340-8T
(20mA)

Device data

Transfer rate:

300 baud

Character format:

1 Start bit
8 Data bits
2 Stop bits

Order No. for PT80 to SINUMERIK
specification:

Type RS232C (V.24) : L22751-A80-

D442
(Interface module
STT104)

Type 20mA :

L22751-A80-D441
(Interface module
STT104+LAT101)

Additional cable
for terminal
connection:
6FC9340-4KA

An NC-controlled read operation (start
/stop) is possible on the device with a
20mA interface.

Siemens printer PT88

Cable Order No.: 6FC9 340-8D.

Device data

Interface adaptation SAP-S1
(RS232C (V.24))

Setting of the operating mode
switches

Switch S1

1

2

3

4

5

6

ON ON ON OFF OFF OFF

(with this setting, the printer has a
transfer rate of 9600 baud)

Switch S2

1

2

3

4

5

6

OFF ON OFF ON OFF ON

(this setting denotes:
BUSY (X2.10) line is switched to BUSY
(X1.25) line, with negative potential)

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02