background image

2 Operation

09.91

2.1.2 SINUMERIK 810T operator interface with external machine control panel

The following values are specified in machine data:

- the max. spindle speed
- the values for the spindle speed

override switch positions.

Feed stop/Feed start

When you operate the ”Feed stop” key:

the feed drives are brought to a standstill

the red ”Feed stop” LED

lights up.

Examples of the use of ”Feed stop”

during operation in ”MDI AUTOMATIC” mode, a block with a fault is discovered

in ”JOG”, ”INC..”,”REPOS” modes, e.g. during repositioning to the contour

to change a tool

to input S, T, H, M functions during setting up (overstore).

When you operate the ”Feed start” key:

the feedrate is accelerated to the value given in the part program.

The following values are specified in machine data:
- the feed and rapid traverse rates
- the values for the feedrate override switch positions
- whether the feedrate override switch is also active

for rapid traverse.

2-30

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)