2 data input – Siemens Sinumerik 810T User Manual

Page 183

Advertising
background image

3 Operating Sequences

11.90

3.1.15 Data input/data output

3.1.15.2 Data input

Operate the ”DATA IN-OUT” softkey in any of the
operation modes:
PRESET / JOG / AUTOMATIC /
INC 1 .... INC 10 000 / REFPOINT.

DATA
IN-OUT

Sequence of operation

This input form is shown, with the input
field for ”Interface for data in” marked
in inverse video.

(( 810T))
(( Bild 37 von Druckerei

einmontieren

or

Select the softkey function ”DATA-IN START”
By doing this you enable the control's receive function.

Now enter:
1” ( for input into interface 1 ) or
2” ( for input into interface 2 )
and store it with the input key.

DATA-IN
START

1

F

2

D

On the upper right-hand side of the CRT the message DIO (Data input/output) is

displayed.

On the Data type: line the data coming from the transmission device (tape reader,

programmer ...) is identified.

The following table explains the types of data that can be loaded into the 810T:

3-80

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Advertising