background image

2 Operation

11.90

2.3.4 ”Reset” with change of operating mode

2.3.4

”Reset” with change of operating mode

When changing from one selected operating mode to another (see Handling, Section
2.3.3.1 and / or Section 2.3.3.2), a ” RESET” can be generated by the control.

The ”RESET” generated by the control when changing has the same effect as if the
”RESET” key had been operated (Section 2.1.1.6 or 2.1.2.1).

The generation of a ”RESET” depends on the modes switched.

Generation of ”RESET” with change of operating mode

(

+

... Reset,

o

... No Reset)

MDI AUTO

MATIC

PRESET

JOG

REPOS

AUTO-
MATIC

INC

...

REF-

POINT

PRESET

MDI AUTO-

MATIC

JOG

REPOS

AUTO-
MATIC

INC

...

REF-

POINT

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

o

o

o

+

+

o

o

o

+

+

o

+

+

+

+

+

+

+

+

+

+

+

o

o

o

o

o

Examples:

1)

When changing from ”AUTOMATIC” to ”JOG” mode, no ”RESET” is generated by the
control!

2)

When changing from ”JOG” to ”REFPOINT” mode, a ”RESET” is generated by the
control!

2-42

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02