4 Monitoring Functions

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

14

”RAM error memory module”

Remarks:

Alarm only on commissioning

Alarm No.

Alarm Text:

16

”Parity error RS232C (V.24)”

Reason:
Effect:
Remedy:

Explanation:

The last character transferred has incorrect parity.
RS232 transfer is interrupted; the last block is not stored
– Check setting data 5011/5013/5019/5021
– Test external device
The alarm only appears when the setting data ”with parity bit” is set.

Alarm No.

Alarm Text:

17

”Overflow error RS232C (V.24)”

Reason:
Effect:

Remedy:

Transfer speed is not correct
– Data transfer is interrupted
– The last block is not stored
– Check setting data 5011/5013/5019/5021
– Check transfer speed (Baud rate)

Alarm No.

Alarm Text:

18

”Frame error RS232C (V.24)”

Reason:

Effect:
Remedy:

– Number of stop bits is incorrect
– Baud rate is incorrect
– Number of data bits is incorrect
– Data transfer is interrupted
– The last block is not stored
– Check setting data 5011/5013/5019/5021
– Test external device

Alarm No.

Alarm Text:

19

”I/O device not ready RS232C (V.24)”

Reason:
Effect:
Remedy

DSR signal has low level.
No data are read in.
– Start external device
– Do not use DSR (isolate cable)

Alarm No.

Alarm Text:

20

”PLC alarm memory not formatted”

Remarks:

Alarm only on commissioning