Siemens Sinumerik 810T User Manual

Page 286

Advertising
background image

6 Data Interfaces

01.93

6.4 Device connection data

Siemens Programmer
PG 685/675/670/730/750

Interface S5 PLC

Cable Order No.:

6FC9 340-8G
6FC9 344-4R
(PG 750/730 only)

Device data

Interface:

20 mA current
loop

Transfer rate:

9600 baud

Character format:

1 Start bit,
7 Data bits,
1 Parity bit (even
parity),
2 Stop bits

Operating conditions

For PLC programming the PG 685/675/
670/750 programmer should be connected
directly to interface 1 (20 mA current loop
interface) on the SINUMERIK 810T.
(If cable 6FC9340-8G is used with the
PG 750, the supplied adaptor must be
used)

Siemens Programmer PG 675/685

Interface Printer

Cable Order No.: 6FC9 344-1A.

Device data

Interface: RS232C

(V.24)

Transfer rate:

1200 baud

Character format:

1 Start bit
8 Data bits
2 Stop bits

Operating conditions

Archiving of NC cycles and programs onto
disk, and the transfer to and from the NC
and the creation of programs is possible
with the PG 675/685.
For data transfer, the PG 675/685 should
be connected from the printer interface to
an RS232C (V.24) interface on the
SINUMERIK 810T.

Siemens programmer PG 615 U with
PG 615 adapter and power pack

Interface PLC

Cable Order No.: 6FC9 340-8H.

Device data

Interface:

20 mA current
loop

Transfer rate:

9600 baud

Character format:

1 Start bit
7 Data bits
1 Parity bit
(even parity)
2 Stop bits

Operating conditions

For PLC programming the PG 615 program-
mer is connected via the adapter and a cable
to interface 1 (20 mA current loop) on the
SINUMERIK 810T.

6-6

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)