3 Operating Sequences

3.2.3 Influencing ”AUTOMATIC” operation

3.2.3

Influencing ”AUTOMATIC” operation

Influencing ”AUTOMATIC” operation (e.g. through programmed functions), is displayed in the
first line of the CRT display.

Display:

STOP: AUTO INTERRUPTED

Interruption of ”AUTOMATIC” operation (program hold),
see Section 3.2.3.4 ”Program Interruption”.

Display:

HOLD: SINGLE BLOCK

The single block has been processed
(with switch position ”Single block - ON”).

Display:

STOP: PROG. STOP M00, M01

Programmed interruption of the program process

with ”Program start”

processing of the program
is continued.

Display:

STOP: READ-IN ENABLE

Read enable is a PLC output signal. When the read enable signal is
removed, the processing of the current NC block is finished. The next
program block is not transferred for processing.

Display:

HOLD: DWELL TIME

Processing of the program is interrupted for the duration of the
programmed dwell time.

Note:

”Feed hold” is not displayed on the CRT!

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

3-93

SINUMERIK 810T, GA3 (BN)