Siemens Sinumerik 810T User Manual

Page 44

Advertising
background image

09.91

2 Operation

2.1.2 SINUMERIK 810T operator interface with external machine control panel

This key enables you to run a program on a block-by-block basis in
the ”AUTOMATIC” operating mode.

When the switch is in position

0

:

Single block operation is
not active!

When the switch is in position

I

:

Single block operation is
active!

When single block operation is active :

the ”SBL” (Single block) message is shown on the first line of
the CRT (2.1.1.1)

the current part program block is
processed only when you press
the ”Program start” key

when the block has been processed, the ”HOLD SINGLE
BLOCK” message is displayed on the CRT

when you operate the ”Program start” key again, the next
block is transferred and processed etc...

Single block switch

I

O

For certain functions (”coordinate rotation”, ”soft approach to contour”),

the control inserts further blocks. Depending on the number of blocks

inserted the ”program start” key must be pressed several times.

The rotary switch, with 16 latched positions, enables you to
decrease or increase the programmed spindle speed ”S”
(relative to 100%).

The actual function of the switch depends on a machine data.

The set spindle speed value ”S” is displayed on the
CRT as an absolute value and as a percentage.

Control range:

50% ..... 120% of the programmed spindle
speed.

Step increment:

5% from position to position.

Spindle speed override switch

50

60

70

80

90

100

110

120

%

S

The step increment and control range specified apply

to standard machine data.