5 Maintenance

5.3 Exchanging the battery in the battery receptacle

Replacing the battery in the battery receptacle

The battery backs up:

The part-program RAM memory

The working memory

The PLC user memory

The machine data memory

The back-up time of the battery is 1 year.

When alarm number ”1” is displayed, the battery should be replaced.

The battery should be exchanged within one week of the alarm appearing.

For the battery type, please see the Instruction Manual. To order, contact your local
Siemens Service Centre.

1) Control must be switched on when replacing battery.
2) When changing, take care that the polarity is correct!
3) When disposing of battery, certain requirements have to be met. Any

enquiries with respect to this should be addressed to the local
authorities.

5.4

CRT display

The picture on the CRT display can oscillate when the monitor is exposed to electromagnetic
fields. Devices which generate electro-magnetic fields, such as transformers, fans, electro-
magnetic switches, a.c. cables under power, etc., must be more than 300 mm away from the
CRT display unit.