Siemens Sinumerik 810T User Manual

Page 269

Advertising
background image

4 Monitoring Functions

01.93

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

3004

”CL800 Error”

Reason:

Remedy:

– @ Function not implemented
– Incorrect address after the @
– Incorrect number of addresses after the @
– Value in K, R or P not permissible
– Number of decades too large
– No decimal point permissible
– Jump destination incorrectly defined
– System line (NC MD, PLC MD, TO ...) does not exist
– Bit number too large
– Incorrect angle data for sine or cosine
– Program as @ list
– Only K, R and P are valid addresses
– Define jump destination forward with ”+”, back with ”-”
– Check validity of data in given addresses
– Select decoded single block (DEC-SBL) and check program again

Alarm No.

Alarm Text:

3005

”Contour definition error”

Reason:

Remedy:

The coordinates in the contour description have been defined so that
no intersection point is given.
As for alarm 3000

Alarm No.

Alarm Text:

3006

”Wrong block structure”

Reason:

Remedy:

– More than 3 M functions have been programmed in one block
– More than 1 S function has been programmed in one block
– More than 1 T function has been programmed in one block
– More than 1 H function has been programmed in one block
– More than 4 auxiliary functions have been program. in one block
– More than 3 axes with G00/G01 have been program. in one block
– More than 2 axes with G02/G03 have been program. in one block
– G04 has been programmed with addresses other than ”X” or ”F”
– M19 has been programmed with addresses other than ”S”
– Invalid, or no interpolation parameters with G02/G03
– G92 P.. not in a block of its own
– G74 not in a block of its own.
– At least one axis and no rotary axes or more than 2 rotary axes are

programmed in a block with active G98 or G36.

– Radius, angle or L or P are programmed in a block with active G36.
– Because of the thread lead and the distance to go of the infeed

axis, the distance to go with G36 for the rotary axis is too large.

– G98 is active, but neither G0, G1 or G36 of G group 0 is active.
– The function TRANSMIT is active for the same rotary axis in a block

with G98 or G36.

– The rotary axis in a block with active G98 or G36 is also selected as

a rotary axis for cylindrical interpolation.

– Contour definition is traversed with G98 feed.
– In a block with active G36 the thread lead is either missing or is not

assigned to the programmed infeed axis.

– An axis switchover command (spindle/rotary axis) is not

programmed alone in a block.

As for alarm 3000 (with axis switchover only possible with RESET)

4-26

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Advertising