Siemens Sinumerik 810T User Manual

Page 260

Advertising
background image

4 Monitoring Functions

01.93

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

2059

”G92 program error”

Reason:

Remedy:

– Use of an invalid address character
– Error on cylindrical interpolation
G92 is only allowed with address ”S” (programmed spindle speed
limitation) or “P” (cylindrical interpolation)

Alarm No.

Alarm Text:

2060

”TO, ZO program error”

Reason:

– A non-existent tool offset number was selected
– The value in the selected zero offset or tool offset is too large

Alarm No.

Alarm Text:

2061

”General program error”

Effect:
Reason:

Inhibiting of NC START
– Contour calculation not possible
– Machine data for ”axis duplication” function incorrect

Alarm No.

Alarm Text:

2062

”Feed missing/not prog.”

Reason:

Remedy:

– No F value programmed
– F value too small (machine data)
– Feed per rev., G95 greater than 50mm/min per revolution
– No feed per rev. programmed
– The axial distance to go for the rotary axis with G98 or G36 is 0 or

no G98 feed has been programmed.

Program correct feed

Alarm No.

Alarm Text:

2063

”Thread lead too high”

Reason:

Effect:
Remedy:

A thread pitch of more than 400 mm/rev.
(16 inch/rev.) has been programmed.
Inhibiting of NC start
Program a smaller thread pitch

4-18

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Advertising