4 Monitoring Functions

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

3042

”Display description error”

{serious error}

Reason:

Remedy:
Explanation:

An error has been found in the display description which cannot be
exactly defined; e. g. a non-existent field has been programmed.
Check the display with the workstation
Only with additional programming via WS 800

Alarm No.

Alarm Text:

3043

”Display description error”

{non serious error}

Reason:
Remedy:
Explanation:

As for alarm 3042
As for alarm 3042
As for alarm 3042

Alarm No.

Alarm Text:

3046

”Variable error”

Reason:
Remedy:
Explanation:

A variable has been selected that cannot be displayed in the control.
Check display with workstation
Only with additional programming via WS800

Alarm No.

Alarm Text:

3048

”Wrong workpiece definition”

Reason:

Remedy:

Minimum and maximum workpiece definition values have been
interchanged.
Check the workpiece definition for valid values

Alarm No.

Alarm Text:

3049

”Wrong simulation area!”

Reason:
Remedy:

Incorrect or no values given for the definition of the simulation area
– Check the values for the simulation area (all planes)
– A new start of simulation is possible after RESET and operation of

the ”ACKNOWLEDGE ALARM” key

Alarm No.

Alarm Text:

3050

”Incorrect input”

Reason:

Incorrect/undefined simulation data

Alarm No.

Alarm Text:

3063

”Data block not available”

Explanation:
Remedy:

A DB No. was selected in PLC STATUS which is not available.
Select or create the correct data block.