3 Operating Sequences

3.2.3 Influencing ”AUTOMATIC” operation

DRY
YES-NO

You select, for example, the ”DRY RUN FEEDRATE” softkey.

Display:

Dry run feedrate

YES

All blocks in which a feedrate is programmed (G01, G02, G03, G33, G34, G35) will now be
traversed at the feedrate value entered into the ”Dry run feedrate” setting data, instead of
the programmed feedrate.
The dry run feedrate then applies to ”Feed per revolution” G95, and the feedrates for
threading (G33,G34,G35).

You select, for example, the ”OPTIONAL STOP” softkey function

OPT.
STOP
YES-NO

Display:

Optional stop

YES

When an ”M01” is present in the part program, the program is stopped.
When the softkey function is marked with ”NO”, ”M01” is ignored.

You select, for example, the ”RAPID OVERRIDE” softkey
function.

OVERR.
YES-NO

Display:

Rapid override

YES

This signal requires that there is a common feedrate/rapid override switch. If the softkey
function is set to ”NO”, this override switch is only active with ”feedrate”. If the softkey
function is set to ”YES”, the override set with this override switch is also effective for rapid
traverse.