Galaxy Pulsar Edge Power System Controller


Issue 3 October 2011

151

REC-Rectifiers

Related

Commands

obj,attr

Description

sta

cha

ope

type

Range of Values

gsr,des

Description

text

Rectifier sr

gsr,typ

Rectifier Type

text

12 char

gsr,sn

Serial number

text

Up to 18 characters

gsr,adc

DC Current (VI, VIR)

number

number A

gsr,vdc

DC Voltage

number

number V

gsr,stt

Individual rectifier state

text

ON*, OFF, STANDBY*,
VACANT*, MISSING

gsr,cap

Capacity

number

number A

gsr,aac

AC Current

number

number A

gsr,vac

AC Voltage

number

number V

gsr,tmp

Temperature

number

number F or C

gsr,seq

Use In Sequence Enable

number

0=no 1=yes

gsr,rfa

Rectifier Fail

number

0=inactive 1=active

gsr,acf

AC Fail

number

0=inactive 1=active

gsr,man

Standby or Manual Off

number

0=inactive 1=active

gsr,did

ID Conflict

number

0=inactive 1=active

gsr,clm

Current Limit

number

0=inactive 1=active

gsr,rif

Internal Fault

number

0=inactive 1=active

gsr,rcf

Communication Fail

number

0=inactive 1=active

gsr,rfn

Fan fail

number

0=inactive 1=active

gsr,lsf

Load Share Fail

number

0=inactive 1=active

s stands for shelf number (1 to 6)
r stands for rectifier number (1 to 7)
* The user may only set the state to ON, STANDBY, or VACANT

Converter Plant

Related

Commands

obj,attr

Description

sta

cha

ope

type

Range of Values

cp1,des

Description

Text

Converter Plant 1

cp1,typ

Converter output type

Text

24V or 48V

cp1,vdc

DC Voltage

Number

Number in volts

cp1,adc

DC Current

Number

Number in amps

cp1,cap

Installed capacity

Number

Number in amps

cp1,olcap

Online capacity

Number

Number in amps

cp1,vsp

Voltage Set-Point

Number

23-28V or 46-57V

cp1,vsd

Internal high voltage shutdown

Number

25-30V or 50-60V

cp1,dth

Low Voltage Discon Threshold

Number

20-25V or 40-50V

cp1,rth

Low Voltage Recon Threshold

Number

22-27V or 44-54V

cp1,lvd

Low Voltage Disconnect Enable

Number

0=disabled 1=enabled

cp1,rss

Converter restart

number

1=restart

cp1,rme

Redundancy monitor enable

number

0=disable,1=enable

Cp1,rof

Remote standby enable

number

0=disable,1=enable

DC Converter

Related

Commands

obj,attr

Description

sta

cha

ope

type

Range of Values

csr,des

Description

Text

DC Converter sr

csr,typ

Type

Text

10 chars

csr,sn

Serial number

Text

Serial number