Inputs - outputs – Micromod RetroPAK: SLC Configuration Manual User Manual

Page 292

Advertising
background image

Command Series Migration to MOD 30ML

Function Code 65 – Digital Sum with Gain

Figure 65 .2.

Function Code 65
Input
Configuration

INPUTS - OUTPUTS

Signal

Block

Type

Description

S1

FC65

Input – S1 Discrete
(Boolean)

Connect to the FC65.S1 signal
of the compound. Input1 to the
summer function.

S2

FC65

Input – S2 Discrete
(Boolean)

Connect to the FC65.S2 signal
of the compound. Input2 to the
summer function

S3

FC65

Input – S3 Discrete
(Boolean)

Connect to the FC65.S3 signal
of the compound. Input3 to the
summer function

S4

FC65

Input – S4 Discrete
(Boolean)

Connect to the FC65.S4 signal
of the compound. Input4 to the
summer function

S5

FC65

Input gain parameter – S5
Floating Point

Connect to the FC65.S1 signal
of the compound. Input1 to the
summer function.

65 - 2

Advertising
This manual is related to the following products: