Spectra Precision Survey Pro v4.5 Ranger Reference Manual User Manual

Page 139

Advertising
background image

Survey Menu – Conventional Mode

R-131

Note: A residual is the difference between a single measurement and
the average of all the measurements.

Note: If a residual exceeds the tolerances set in the Repetition
Settings screen (Page R-53), that value is displayed in bold text.

HA , ZA , SD : allows you to replace the current repetition data for

the corresponding button with new data. Once tapped, the repetition

data for the tapped button will be deleted. You will then need to

perform all sets defined in the Number of Sets field again, where the
new data will replace the corresponding deleted data.

All : will open a screen that asks if you want to add an additional set

to those already done or start over.

Toss : will delete the corresponding set that has the worst residual.

Note: A set can only be “tossed” when three or more sets have been
collected.

Side Shot : will use the repetition data gathered to create a new side

shot point. The foresight point will automatically advance to the next

available point.

Traverse : will use the repetition data gathered to create a new

traverse point. The occupy point will automatically update to the
previous foresight point and the backsight point will automatically

update to the previous occupy point.

Backsight… : opens the Backsight Setup screen (Page R-118) where

the current backsight can be modified.

Note: The current backsight information is displayed across the top
of the Repetition Shots screen.

Advertising