Survey Menu – Conventional Mode

R-163

Lock : puts the total station in track mode where it will track the

movements of the prism.

Stop : stops the total station from tracking or searching.

Turn To : opens the Turn To screen (Page R-163) where the total

station can be turned to a specified direction or quickly flipped
between face one and face two.
EDM Mode: allows you to select from various EDM modes. The
options available depend on the total station being used. Consult the

total station’s documentation for more information on the EDM

modes that it supports.

Turn To

Survey Remote Control Turn To

.

The Turn To screen is used to turn a robotic
total station to a specified horizontal and

zenith angle, or to a specified point.
Horizontal Angle: is the horizontal angle that
the total station will turn to.
Zenith Angle: is the zenith angle that the total
station will turn to.

Turn to Angles : turns the total station to the

specified horizontal and zenith angles.
Existing Point: is the point from the current

job that the total station will turn to.

Turn to Point : turns the total station to the specified point.

Turn to Backsight : turns the total station to the backsight point.

Flip : quickly rotates the total station from face one to face two, or

vice versa.

Aim : opens a screen where the instrument can be aimed more

precisely. (Page R-168)