Turn to benchmark – Spectra Precision Survey Pro v4.5 Ranger Reference Manual User Manual

Page 274

Advertising
background image

Survey Pro Reference Manual

R-266

Turn to Benchmark

Leveling Level

Turn to Benchmark

.

The Turn to Benchmark screen is used to take a shot at a known

benchmark. When shooting a benchmark that will not be used as the
closing benchmark, the procedure is identical to shooting a leveling

side shot with the exception that this benchmark will be the

backsight in the next setup.
BM Point: is the point name for the
benchmark. This will usually be a new point

when it is a non-closing benchmark and will

usually be the same point as the starting
benchmark when it is the closing benchmark.
Desc: is the optional description for the
benchmark. This is not applicable when

shooting the closing benchmark since the

closing benchmark must already exist in the
current job.
Default Location for New Points: is where
you specify the northing and easting to use when shooting a new

point. This is not applicable when shooting the closing benchmark.
Backsight Point: Lists the details for the current backsight. If this is

the first observation from the current set up, most of the details will
be unknown.

Next > : opens the Take Shot screen (Page R-262) where the

required shots are performed. If the shots are taken to an existing
point, such as when shooting the closing benchmark, the Point Exists

screen, described next, will open where the loop can be closed.

Advertising