background image

Survey Pro Reference Manual

R-184

Receiver Antenna

The Receiver Antenna screen is used to define
the parameters of the antenna used with the

current receiver. This screen may be opened

as the Base Receiver Antenna, Rover Receiver
Antenna, or the Post Processing Antenna

screen.

Antenna Type

: is where you select the model of

antenna to use. The options available here

depend on the current receiver.

Measure To

: is where you select method for

antenna height measurements. Most antennas

have only two choices, measure to bottom of mount, or a visible slant
measure mark.

Measured

: is where you enter the height of the antenna, measured to

the location specified in the Measure To field.

Radius

: is where you enter the distance from the antenna’s center to

the measuring mark on its outer edge.

Offset

: is where you enter the vertical distance measured from the

Measure To

location, to the phase center.

Serial#

: is the serial number of the antenna. This information is only

written as a note in the raw data.

Notch

: Is the notch number on the antenna that you are measuring

to.

Note: If your antenna type is Manual, the Radius and Notch fields
will not be available

Set : Updates the base antenna settings with the values selected on

this screen.