Spectra Precision Survey Pro v4.5 Ranger Reference Manual User Manual

Page 260

Advertising
background image

Survey Pro Reference Manual

R-252

show the root mean squared (RMS) error of the horizontal

and vertical solution.

Yellow Warning Triangle: If the localization solved and no

blunders were detected, but some of the points used have a

large residual error, you will see a yellow triangle and the

status line will show the point with the largest horizontal
and/or vertical residual.

Red Stop Sign: If the localization solved, and blunders were

detected that could not be clearly identified, or if you were

prompted to remove blunders and you said no, then you will

see a red stop sign and the status line will indicate there are
possible blunders in the solution.

Yellow Arrow: If the localization solved, but the control

points are not spaced far enough apart to run the automatic

blunder detection, then you will see a yellow arrow, and the

status line will indicate the poor geometry of the control
points, or if the localization fails to solve, you will see a yellow

arrow and the status the status line will indicate the failure

to solve the localization.

Finish : will solve the localization. If any of the horizontal or vertical

control toggles are changed in this screen before tapping Finish, the
button will change to Resolve, allowing you to re-compute the quality
before continuing.

Occupy Additional Check Point : opens the Occupy Control screen

(Page R-255), which allows you to collect another control point and
add it to the localization solution.