Level Menu

R-269

to take next. The term A1 means to shoot the rod over Point A for Set
1. If the box showed B3, it would mean to shoot the rod over Point B
for Set 3.

Take Shot : takes the shot indicated within the box on this screen.

Peg Test Results

The Peg Test Results screen appears after all

the required shots are performed for a peg test.

The screen lists the details for all the shots
taken and the computed error. All the shots

taken and the error are recorded only in the

raw data file.



Adjustment

Leveling Adjustment

.

The Adjustment routine allows you to perform
a simple arithmetic elevation error adjustment

to an existing closed loop. You can choose to

distribute the error equally to each setup, or
apply a weighted adjustment proportional to

the distance between each setup. You also

have the option to adjust any side shots that
were performed in the selected loop.
Weigh by # of Setups: This option divides the
computed error equally among each setup

selected in the loop.

Weigh by Length of Setups: This option distributes the error where

each setup is adjusted by an error proportional to the length between