Survey Pro Reference Manual

R-200

Start Stop/Go

: use this setting if you want to start a log file in stop

and go mode, where the receiver will rove around. In stop and go

mode, the GPS raw data is continuously logged to the file to maintain
the initialization while roving around, this is the go part. Then,

static sessions are marked when the receiver is stationary over a

point, this is the stop part.

Recording Settings

: this area displays values from the Job | Settings

| Post Processing screen.

Change : opens the Job | Settings | Post Processing screen, where

you can modify the settings relevant to post processing data

collection.

Rec Interval

: displays the current recording interval for new logging

files.

Mem. Threshold

: displays the current minimum memory on disk

available before a warning is issued.

SV Threshold

: displays the current minimum number of satellites

tracked before a warning is issued.

HDOP Threshold

: displays the maximum HDOP allowed before a

warning is issued

Antenna

: displays antenna setup for this receiver. It will be in one of

two states:

• Last Antenna for this receiver: is displayed when you have not

yet set this receiver in Survey Pro. This value is the previous

antenna measurement you used with this receiver.

• Selected

Antenna

: is displayed when you have entered new

antenna measurements using the Receiver Antenna screen

(Page R-184)

Measured

: is where you enter the measured antenna height (for the

specified measure to mark).

Offset

: is the reduced offset (slant correction plus phase center offset)

for the currently selected antenna type and measure to mark.

Setup HR: opens the Receiver Antenna screen (Page R-184), where

you can change the antenna type, measure to mark, and offsets.