36 troubleshooting – Rockwell Automation 1557 MEDIUM VOLTAGE AC DRIVE User Manual

Page 278

Advertising
background image

10-36

TROUBLESHOOTING

1557-UM050F-EN-P – June 2013

Drive Faults

Fault

Code #

FAULT

MESSAGE

F

Description

F44

Over temp 5

F

Heatsink over temperature is present, 85 degrees centigrade exceeded.

F45

Over temp 6

F

Heatsink over temperature is present, 85 degrees centigrade exceeded.

F46

Over temp 7

F

Heatsink over temperature is present, 85 degrees centigrade exceeded.

F47

Firmware rev

F

Firmware in the two drive control boards or the communication
processor board is not compatible.

F256

Drv o/l warn

W The drive overload protection has reached 50% of the trip value in

P163.

F257

Mtr o/l warn

W The motor overload level has reached 50% of the trip value in P179.

F258

Line u/v

W The line voltage has fallen below the level in P167 for the duration in

P168.

F259

Line rev seq

W The drive attempted to make a synchronous transfer with reverse

sequence line voltage. Sync transfer cancelled.

F260

Input open

W The input contactor is open when it is requested to be closed

F261

Input closed

W The input contactor is closed when it is requested to be open

F262

Output open

W The output contactor is open when it is requested to be closed.

F263

Output closed

W The output contactor is closed when it is requested to be opened.

F264

Bypass open

W The bypass contactor is open when it is requested to be closed.

F265

Bypass closed

W The bypass contactor is closed when it is requested to be open.

F266

Tach loss

W The tach signal has been lost to the tach feedback board.

F267

H/w o/c warn

W Hardware overcurrent warning. The DC O/C trip level (P169) has

been exceeded. A GTO gate freeze will be initiated.

F268

H/w o/v warn

W Hardware overvoltage warning. The DC O/V trip level (P187) has

been exceeded. A GTO gate freeze will be initiated.

F269

Tach rotn

W Phase A and B of the tachometer is interchanged.

F270

Line sync

W The line converter gating has lost synchronization with the line

voltage.
The drive will shut off momentarily and restart.

F271

dc\dc warn

W The dc\dc converter has reported a failure in one of the redundant

outputs. The threshold for fail condition is 95% of rated output
voltage.

F272

Rated rpm

W Rated motor rpm parameter P26 has been set to an invalid value.

F273

PWM too high

W The PWM frequency parameter P155 has been set too high for the

drive ratings. It will be changed to a lower value.

F274

Rated I fbk

W The current feedback scaling is out of range.

F275

Filter cap

W The per unit filter capacitor is out of range. Value must fall within the

range 0.25 per unit to 0.75 per unit.

F276

Not used

F277

Not used

F278

Not used

F279

Not used

F280

Not used

F281

Fan Loss

W The output of the static pressure sensor fell below the level in P175

for the duration in P176.

Advertising