Altera ALTPLL (Phase-Locked Loop) IP Core User Manual

Page 47

Advertising
background image

Description

Type

Parameter

Specifies the initial value for the corresponding counter,

C[9..0]

. If omitted, default is

1

. Counters

C[9..5]

are

not available in Cyclone III devices onwards.

Integer

C[]_INITIAL

Specifies the value of the low period count for the
corresponding counter,

C[9..0].

If omitted, default is

1

.

Counters

C[9..5]

are not available in Cyclone III devices

onwards.

Integer

C[]_LOW

Specifies the operation mode for the counter,

C[9..0]

.

The values are

BYPASS

,

ODD

, or

EVEN

. If omitted, the default

is

BYPASS

. Counters

C[9..5]

are not available in Cyclone

III devices onwards.

String

C[]_MODE

Specifies the phase tap for the counter,

C[9..0]

. If omitted,

default is

0

. Counters

C[9..5]

are not available in Cyclone

III devices onwards.

Integer

C[]_PH

Specifies the test source for the counter,

C[9..0]

. If

omitted, default is

0

. Counters

C[9..5]

are not available

in Cyclone III devices onwards.

Integer

C[]_TEST_SOURCE

Specifies whether to use cascade input for the counter,

C[9..1]

. Values are

ON

or

OFF

. If omitted, default is

OFF

.

Counters

C[9..5]

are not available in Cyclone III devices

onwards.

String

C[]_USE_CASC_IN

Specifies the value of the charge pump current in
microamperes (mA).

Integer

CHARGE_PUMP_CURRENT

Specifies the counter for the corresponding output clock
port,

CLK[9..0]

. Values are

UNUSED

,

C0

,

C1

,

C2

,

C3

,

C4

,

C5

,

C6

,

C7

,

C8

or

C9

. If omitted, the default is

C0

. This parameter

is not available for Cyclone II and Stratix II devices.
Counters

CLK[9..5]_COUNTER

are not available for Cyclone

III devices onwards.

String

CLK[]_COUNTER

Specifies the integer division factor for the VCO frequency
of the corresponding output clock port,

CLK[9..0]

port.

The parameter value must be greater than

0

. Specify this

parameter only if the corresponding

CLK[9..0]

port is

used; however, it is not required if a Clock Settings
assignment is specified for the corresponding

CLK[9..0]

port. If omitted, the default is

0

. Parameters

CLK[9..5]_

DIVIDE_BY

are not available in Cyclone III devices.

Integer

CLK[]_DIVIDE_BY

Specifies the duty cycle in percentage for the corresponding
output clock port,

clk[9..0]

. If omitted, the default is

50

.

Parameters

CLK[9..5]_DUTY_CYCLE

are not available in

Cyclone III devices.

Integer

CLK[]_DUTY_CYCLE

Altera Corporation

ALTPLL (Phase-Locked Loop) IP Core User Guide

Send Feedback

47

ALTPLL Parameters

ug-altpll