Altera ALTPLL (Phase-Locked Loop) IP Core User Manual

Page 60

Advertising
background image

Description

Type

Parameter

Specifies whether the

fbmimicbidir

port is used. Values

are

ON

or

OFF

. If omitted, the default is

OFF

.

For Stratix III and Stratix IV device families, with the

OPERATION_MODE

parameter set to

ZERO_DELAY_BUFFER

,

and the

USING_FBMIMICBIDIR_PORT

parameter is set to

OFF

, you must perform the following steps:

1. Instantiate an ALT_IOBUF IP core.
2. Connect the

fbout

and

fbin

ports to the

o

and

i

ports

of the ALT_IOBUF instantiation, respectively.

3. Connect the bidirectional port of the ALT_IOBUF

instantiation to a bidirectional pin, and set the

oe

port

of the ALT_IOBUF instantiation to

1

.

If the

OPERATION_MODE

parameter is set to

ZERO_DELAY_

BUFFER

, and the

USING_FBMIMICBIDIR_PORT

parameter is

set to

ON

, connect the

fbmimicbidir

port to a bidirectional

pin. This pin must be placed on the positive feedback
dedicated output pin of the PLL.

String

USING_FBMIMICBIDIR_PORT

Specifies the scaling factor, in half-clock cycles, for which
the clock output ports must be locked before the locked
pin goes high.

Integer

VALID_LOCK_MULTIPLIER

Specifies the center value for the VCO pin. Use for
simulation purposes only.

Integer

VCO_CENTER

Specifies the integer division factor for the VCO pin. If
omitted, the default is

0

. If

VCO_FREQUENCY_CONTROL

is set

to

MANUAL_PHASE

, specify the VCO frequency as a phase

shift step value; that is, one-eighth of the VCO period.

Integer

VCO_DIVIDE_BY

Specifies the integer division factor for the VCO pin. If
omitted, the default is

0

. If

VCO_FREQUENCY_CONTROL

is set

to

MANUAL_PHASE

, specify the VCO frequency as a phase

shift step value; that is, one-eighth of the VCO period.

Specifies the frequency control value for the VCO pin.
Values are

AUTO

,

MANUAL_FREQUENCY

, and

MANUAL_PHASE

.

If omitted, the default is

AUTO

.

AUTO

VCO_MULTIPLY_BY

and

VCO_DIVIDE_BY

values

are ignored and VCO frequency is set automatically.

MANUAL_FREQUENCY

—Specifies the VCO frequency as

a multiple of the input frequency.

MANUAL_PHASE

—Specifies the VCO frequency as a phase

shift step value.

String

VCO_FREQUENCY_CONTROL

Specifies the maximum value for the VCO pin. Use for
simulation purposes only.

Integer

VCO_MAX

ALTPLL (Phase-Locked Loop) IP Core User Guide

Altera Corporation

Send Feedback

ug-altpll

ALTPLL Parameters

60

2014.08.18

Advertising