Altera ALTPLL (Phase-Locked Loop) IP Core User Manual

Page 53

Advertising
background image

Description

Type

Parameter

Specifies the modulus for the

M

counter. Provides direct

access to the internal PLL parameters. If the

M

parameter

is specified, all advanced parameters must be used. Values
range from

1

to

512

. If omitted, the default is

0

.

Integer

M

Specifies the initial value for the

M

counter. Provides direct

access to the internal PLL parameters. If the

M_INITIAL

parameter is specified, all advanced parameters must be
used. Values range from

0

to

512

. If omitted, the default

is

0

.

Integer

M_INITIAL

Specifies the phase tap for the M counter. Values range
from 0 to 7. If omitted, the default is

0

.

Integer

M_PH

Specifies the test source for the

M

counter. If omitted,

default is

5

.

Integer

M_TEST_SOURCE

Specifies, in nanoseconds (ns), the time delay for the

M

counter. Values range from

0

ns through

3

ns. If omitted,

the default is

0

. This parameter is not available for Cyclone

II and Stratix II devices.

Integer

M_TIME_DELAY

Specifies the spread spectrum modulus for the

M

counter.

Provides direct access to the internal PLL parameters. If
the

M2

parameter is specified, all advanced parameters must

be used. Values range from

1

to

512

. If omitted, the value

is

1

.

Integer

M2

Specifies the modulus for the

N

counter. Provides direct

access to the internal PLL parameters. If the

N

parameter

is specified, all advanced parameters must be used. Values
range from

1

to

512

. If omitted, the default is

1

.

Integer

N

Specifies, in nanoseconds (ns), the time delay for the

N

counter. Values range from

0

ns through

3

ns. If omitted,

the default is

0

. This parameter is not available for

Cyclone II and Stratix II devices.

Integer

N_TIME_DELAY

Specifies the spread spectrum modulus for the

N

counter.

Provides direct access to the internal PLL parameters. If
the

N2

parameter is specified, all advanced parameters must

be used. Values range from

1

through

512

. If omitted, the

default is

1

.

Integer

N2

Altera Corporation

ALTPLL (Phase-Locked Loop) IP Core User Guide

Send Feedback

53