Altera ALTPLL (Phase-Locked Loop) IP Core User Manual
Page 52
Description
Type
Parameter
Specifies the high period count for the corresponding
L[1..0]
counter. Values range from
1
to
512
. If omitted,
the default is
1
.
Integer
L[]_HIGH
Specifies the initial value for the corresponding
L[1..0]
counter. Values range from
1
to
512
. If omitted, the default
is
1
.
Integer
L[]_INITIAL
Specifies the low period count for the corresponding
L[1..0]
counter. Values range from
1
to
512
. If omitted,
the default is
1
.
Integer
L[]_LOW
Specifies the mode for the corresponding
L[1..0]
counter.
Values are
BYPASS
,
ODD
or
EVEN
. If omitted, the default is
BYPASS
.
String
L[]_MODE
Specifies the phase tap for the corresponding
L[1..0]
counter. Values range from
0
to
7
. If omitted, the default
is
0
.
Integer
L[]_PH
Specifies, in nanoseconds (ns), the time delay for the
corresponding
L[1..0]
counter. Values range from
0
ns
to
3
ns. If omitted, the default is
0
.
String
L[]_TIME_DELAY
Specifies the number of half-clock cycles that the output
clocks must be locked before the
locked
port goes high.
This parameter is required for simulation in third-party
simulators. Available for Stratix IV, Stratix III, Cyclone IV,
and Cyclone III devices only.
Integer
LOCK_HIGH
Specifies the number of half-clock cycles that the output
clocks must be out-of-lock before the
locked
port goes
low. This parameter is required for simulation in third-
party simulators. Available for Stratix IV, Stratix III,
Cyclone IV, and Cyclone III devices only.
Integer
LOCK_LOW
Specifies the value of the
LOCK_WINDOW_UI
setting. If
omitted, default is
0.05
.
String
LOCK_WINDOW_UI
Specifies, in picofarads (pF), the value of the loop capacitor.
Values range from
5
to
20
pF. The Compiler cannot achieve
all values. If omitted, the default value is
10
.
String
LOOP_FILTER_C
Specifies, in kilo ohms (K Ohm), the value of the loop
resistor. Values range from
1
K to
20
K. The Compiler
cannot achieve all values.
String
LOOP_FILTER_R
Allows you to specify Altera-specific parameters in VHDL
Design Files (.vhd). The default is
UNUSED
.
String
LPM_HINT
Identifies the library of parameterized modules (LPM)
entity name in VHDL Design Files.
String
LPM_TYPE
ALTPLL (Phase-Locked Loop) IP Core User Guide
Altera Corporation
ug-altpll
ALTPLL Parameters
52