Altera ALTPLL (Phase-Locked Loop) IP Core User Manual

Page 52

Advertising
background image

Description

Type

Parameter

Specifies the high period count for the corresponding

L[1..0]

counter. Values range from

1

to

512

. If omitted,

the default is

1

.

Integer

L[]_HIGH

Specifies the initial value for the corresponding

L[1..0]

counter. Values range from

1

to

512

. If omitted, the default

is

1

.

Integer

L[]_INITIAL

Specifies the low period count for the corresponding

L[1..0]

counter. Values range from

1

to

512

. If omitted,

the default is

1

.

Integer

L[]_LOW

Specifies the mode for the corresponding

L[1..0]

counter.

Values are

BYPASS

,

ODD

or

EVEN

. If omitted, the default is

BYPASS

.

String

L[]_MODE

Specifies the phase tap for the corresponding

L[1..0]

counter. Values range from

0

to

7

. If omitted, the default

is

0

.

Integer

L[]_PH

Specifies, in nanoseconds (ns), the time delay for the
corresponding

L[1..0]

counter. Values range from

0

ns

to

3

ns. If omitted, the default is

0

.

String

L[]_TIME_DELAY

Specifies the number of half-clock cycles that the output
clocks must be locked before the

locked

port goes high.

This parameter is required for simulation in third-party
simulators. Available for Stratix IV, Stratix III, Cyclone IV,
and Cyclone III devices only.

Integer

LOCK_HIGH

Specifies the number of half-clock cycles that the output
clocks must be out-of-lock before the

locked

port goes

low. This parameter is required for simulation in third-
party simulators. Available for Stratix IV, Stratix III,
Cyclone IV, and Cyclone III devices only.

Integer

LOCK_LOW

Specifies the value of the

LOCK_WINDOW_UI

setting. If

omitted, default is

0.05

.

String

LOCK_WINDOW_UI

Specifies, in picofarads (pF), the value of the loop capacitor.
Values range from

5

to

20

pF. The Compiler cannot achieve

all values. If omitted, the default value is

10

.

String

LOOP_FILTER_C

Specifies, in kilo ohms (K Ohm), the value of the loop
resistor. Values range from

1

K to

20

K. The Compiler

cannot achieve all values.

String

LOOP_FILTER_R

Allows you to specify Altera-specific parameters in VHDL
Design Files (.vhd). The default is

UNUSED

.

String

LPM_HINT

Identifies the library of parameterized modules (LPM)
entity name in VHDL Design Files.

String

LPM_TYPE

ALTPLL (Phase-Locked Loop) IP Core User Guide

Altera Corporation

Send Feedback

ug-altpll

ALTPLL Parameters