Rear panel – ATEIS DIVA8G2 User Manual

Page 128

Advertising
background image

DIVA system

128

© 2012 ATEÏS

4.3.1.3

Rear panel

DC Fuse Receptacles:

Two DC fuse receptacles are located on the left of the amplifier’s rear panel. To access each fuse,
unscrew the cap with a screwdriver. For 115 V operations please use T2.5A fuses. For 230 V
operations please use T1.25A fuses.

Power Switch:

The power switch is located at the left of the rear panel and is a two position switch. Pushing up the
power switch (I is pushed) will power on the device, pushing it down (0 is pushed) will power it off.
When the power switch is on the I position, the front panel power LED will be lit.

Channel 1/2 24VDC battery backup connector:

The SPA amplifier can be operated with battery backup. Use the channel 1 and channel 2 “24VDC
Battery Backup” connector to do so. These connectors are located on the upper part of the channel
connectors on the rear panel.

This 24VDC power supply can be used where no AC power is available. When in use, the front panel
Power LED will be lit as well as the front panel DC LED.

AC Power Inlet:

The 3 pin IEC connector is located on the left of the amplifier’s rear panel. It accepts a standard
mains power lead fitted with an IEC connector.

For 115 V, fuse rating:

SPA 2060: 2.5A

SPA 2120: 5A

SPA 2240: 8A

For 230 V, fuse rating:

SPA 2060: 1.25A

SPA 2120: 2.5A

SPA 2240: 5A

Channel 1/2 Audio Output:

Advertising