Evacuation inputs:

Evacuation inputs are contact inputs that allows the monitoring of external contact. They also can
be used in UGA mode, trigger by a voltage polarization change. This connector supplies a 24VDC
source.

RS232 Connector:

SUBD-9 connector that includes two RS232 ports.

Ethernet Connector:

RJ-45 Connector to link the DIVA master to the ethernet network for software configuration and/or to
enable IP paging.

Power Section:

Insert provided power cable first into DIVA8M then in the wall power connector. 110~240 V 1.2A,
47~63Hz AC power input with fuse.
Fuse rating: 1.6 A

Logic output:

Eight Logic outputs to send a pulse or a static closing/opening to an external device.

Evac & Fault contacts:

Evac and fault output contact reflect the evacuation status and the general fault status of the DIVA
system.

Amplifiers I/O:

Voice Amp connector include the 0dB channel to power amplifier and the 100V audio channel from
power amplifier. Same for Music Amp. Music amplifier channel will be used, in case of defect on the
Voice amplifier channel, as a backup amplifier channel.

100V Signal links:

100V output to send 100V signal to others DIVA(M or S) unit.

Speaker zone outputs:

Eight speaker zone connectors split into A and B line.

PSS/PSM connector:

RJ-45 connector to link PSS or PSM call-stations.

Master-Slave link:

RJ-45 connector to create a master-slave DIVA system.

Remote Ext. connector:

not used.

Mic/line input:

XLR connector to plug a microphone or a third line level audio source.