background image

DIVA system

182

© 2012 ATEÏS

General options:

18K/20K Monitor Setting

o

Frequency (Hz): Here you can choose 18K or 20K.

o

Active Mode: There are two options for the monitoring process: "Periodic" and "Only once a
day". In order to comply with EN54 standards, the monitoring active mode should only be
Periodic. If the "Only once a Day" option is chosen, you have to specify at what time the
monitoring process will be activated with the "Active Monitor Period".

o

Monitoring Period: If front knob attenuators are in use and if the attenuation value is -16 or -
20 dB, the monitoring for accuracy purposes will only occur every Monitoring period. By
default, this option is set to 90s. Be carefull that for standard compliancy, this setting should
be manipulate with care and accordance to standard.

o

Continuous Mode: If it's enable, it keeps monitoring.

o

Active Monitor period: Day time where the monitoring "Only once a day" will take act.

1K Monitor Setting