ATEIS DIVA8G2 User Manual

Page 179

Advertising
background image

System Functionality

179

© 2012 ATEÏS

Tick the check box in order to enable the relay.

Set the contact pulse length, range 50ms to 6000ms.

Select on each device (master and/or slaves) the output channel that will be used as Start
Impulse contact. Note: multiple output channels can be selected for an event.

Use Bypass Relay

The bypass relays are independent of events. The goal of bypass relay is to close/open a relay when
some zone(s) are occupied with a type of source.

In order to set a bypass relay, follow the next few steps:

Go in menu View -> GPIO -> Bypass Relay tab

o

Channel 1 to 8: Correspond to the output channel.

o

Activations: Specify if the contact will be closed when active or opened when active.

o

Settings: By clicking on the edit button, you will enter the zone/source matrix.