Bypass: Clicking on the bypass button will instantaneously bypass the compressor-limiter.

o

Soft Knee: If the soft knee button is pressed, a soft knee will be applied to the compressor-
limiter instead of a hard knee.

o

Compressing: This will indicates if the compression is acting or not.

o

Limiting: This will indicates if the limiter is acting or not.

o

Ratio(Comp)x:1: H ere you can specify the compression ratio either by using the slide bar,
arrow key or by entering directly the value in the dedicated cell. Note: this parameter will have
no action if the filter type is set as limiter.

o

Ratio(Limiter)x:1: Here you can specify the limiter ratio either by using the slide bar, arrow
key or by entering directly the value in the dedicated cell. Note: this parameter will have no
action if the filter type is set as compressor.

o

Threshold (dB): Here you can specify the threshold level from where the limiter or
compressor will start acting.

o

Threshold range (dB): Here you can specify the range of level, in which the ratio gradually
alters from 1:1 to the value set by the ratio parameter (soft knee function)either by using the
slide bar, arrow key or by entering directly the value in the dedicated cell.

o

Response time (10ms): Here you specify the attack time for the compressor-limiter.

o

Recovery time (10ms): Here you can specify the release time for the compressor-Limiter