Control Outputs (Logic outputs) are simple contact that when closing link the OUTPUT connector to the
COM connector.

Wiring

The following schematic show a way to create an indicator LED.

4.1.1.5.5 H) Amplifiers I/O

The connection to amplifier can slightly change according to the amplifier model used.

The 0dB output of DIVA are named as follow:

AIN+: for positive 0dB output

AIN-: for negative 0dB output

GND: for 0dB ground output

The 100V input are named as follow:

AOUT+: for positive 100V input

AOUT-: for negative 100V input

Wiring

According to the schematic below, the DIVA 0dB output are linked to the amplifier 0dB input and the
DIVA 100V input are linked to the amplifier 100V output.

Depending on the configuration needed, you can use the amplifier fault output to force DIVA to enter
security mode in case of amplifier failure.