Create a monitorable button – ATEIS DIVA8G2 User Manual

Page 163

Advertising
background image

System Functionality

163

© 2012 ATEÏS

Next Event: Here you can select the event to start after the current one is finished

Start Impulse: Ticking this option allows user to close an output contact (Logic Output channel)
in two different manner. Static will close it until the event stop and Pulse will generate a closing
pulse whose length can be defined from 50 to 60000 ms.

Stop Impulse: This option is used to create a closing contact pulse when the event is finished.
The length of the pulse can be defined from 50 to 60000 ms.

ACK Relay: Here you can set the closing of a Logic Output Channel relay as soon as zones
where an event has to be played are freed from higher priority events.

Busy Relay: Here you can specify an Logic Output Channel relay that will be closed as soon as
a higher priority event is playing in common zones. To learn more about output relay, please read
the How To Use Output Relay.

Message: By using the drop down menu, you can select, in the list of stored message, a
message to assign to the event

Play Mode: By ticking continuous, the message will be played until a trigger happen. You can
also specify a number of repeat time.

Conflict: You can choose between Cancel All or Coexist

Repeat Time: If continuous not ticked, you can choose a number of time this event will be
repeated

Pre-define Zone: Here you can specify the pre-define zone(s) where the message will be played

Zone Selection: Here you can specify the zone(s) where the call will be played

OK: Will accept the current setting and close the window

Cancel: Will annulled the current settings and close the window.

Note: Messages can only be seen if they are a part of the configuration. Reading the message
memory of the DIVA does not put messages in the configuration. You'll have to reverse the
messages in order to be able to use them in the configuration.

5.2.9

Create a Monitorable Button

The surveillance of a contact line, a microphone line or speaker line is based on the same measurement.
An internal voltage source is applied to the input or output terminal. By measuring this tension, it is
possible to know the state of the input or output.

With a normal contact (see picture below), you only will be able to measure two states: Open or
Shorten. Shorten (when contact is closed) forces the voltage source to zero.

Advertising