2-1

2

Logging In Through the Console Port

When logging in through the Console port, go to these sections for information you are interested in:

z

Introduction

z

Setting Up the Connection to the Console Port

z

Console Port Login Configuration

z

Console Port Login Configuration with Authentication Mode Being None

z

Console Port Login Configuration with Authentication Mode Being Password

z

Console Port Login Configuration with Authentication Mode Being Scheme

The default system name of an H3C S5120-SI series Ethernet switch is H3C, that is, the command line

prompt is H3C. All the following examples take H3C as the command line prompt.

Introduction

To log in through the Console port is the most common way to log in to a switch. It is also the

prerequisite to configure other login methods. By default, you can log in to an H3C S5120-SI series

Ethernet switch through its Console port only.

To log in to an Ethernet switch through its Console port, the related configuration of the user terminal

must be in accordance with that of the Console port.

Table 2-1

lists the default settings of a Console port.

Table 2-1 The default settings of a Console port

Setting

Default

Baud rate

9,600 bps

Flow control

Off

Check mode

No check bit

Stop bits

1

Data bits

8

After logging in to a switch, you can perform configuration for AUX users. Refer to

Console Port Login

Configuration

for details.