Configuring the rmon alarm function, Configuration prerequisites, Configuration procedure – H3C Technologies H3C S5120 Series Switches User Manual

Page 595

Advertising
background image

1-5

z

The entry-number must be globally unique and cannot be used on another interface; otherwise, the

operation fails.

z

You can configure multiple history entries on one interface, but the values of the entry-number

arguments must be different, and the values of the sampling-interval arguments must be different

too; otherwise, the operation fails.

z

You can create up to 100 history entries for the device.

z

When you create an entry in the history table, if the specified buckets number argument exceeds

the history table size supported by the device, the entry will be created. However, the validated

value of the buckets number argument corresponding to the entry is the history table size

supported by the device.

Configuring the RMON Alarm Function

Configuration Prerequisites

z

If you need to configure that the managed devices send traps to the NMS when it triggers an alarm

event, you should configure the SNMP agent as described in SNMP Configuration before

configuring the RMON alarm function.

z

If the alarm variable is the MIB variable defined in the history group or the Ethernet statistics group,

you must make sure that the RMON Ethernet statistics function or the RMON history statistics

function is configured on the monitored Ethernet interface; otherwise, the creation of the alarm

entry fails, and no alarm event is triggered.

Configuration Procedure

Follow these steps to configure the RMON alarm function:

To do…

Use the command…

Remarks

Enter system view

system-view

Create an event entry in the event
table

rmon event entry-number [ description
string ] { log | log-trap log-trapcommunity |
none | trap trap-community } [ owner text ]

Required

Create an entry in the alarm table

rmon alarm entry-number alarm-variable
sampling
-interval { absolute | delta }
rising-threshold threshold-value1
event-entry1 falling-threshold
threshold-value2 event-entry2 [ owner
text ]

Create an entry in the private
alarm table

rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-interval
{ absolute | changeratio
| delta } rising-threshold threshold-value1
event-entry1
falling-threshold
threshold-value2 event-entry2
entrytype
{ forever | cycle cycle-period } [ owner
text
]

Required

Use at least one
command.