Network diagram, Configuration procedure – H3C Technologies H3C S5120 Series Switches User Manual

Page 53

Advertising
background image

2-14

Network diagram

Figure 2-7 Network diagram for AUX user interface configuration (with the authentication mode being

scheme)

Configuration procedure

# Enter system view.

<Sysname> system-view

# Create a local user named guest and enter local user view.

[Sysname] local-user guest

# Set the authentication password to 123456 (in plain text).

[Sysname-luser-guest] password simple 123456

# Set the service type to Terminal.

[Sysname-luser-guest] service-type terminal

[Sysname-luser-guest] quit

# Enter AUX user interface view.

[Sysname] user-interface aux 0

# Configure to authenticate the user logging in through the Console port in the scheme mode.

[Sysname-ui-aux0] authentication-mode scheme

# Set the baud rate of the Console port to 19200 bps.

[Sysname-ui-aux0] speed 19200

# Set the maximum number of lines the screen can contain to 30.

[Sysname-ui-aux0] screen-length 30

# Set the maximum number of commands the history command buffer can store to 20.

[Sysname-ui-aux0] history-command max-size 20

# Set the timeout time of the AUX user interface to 6 minutes.

[Sysname-ui-aux0] idle-timeout 6

After the above configuration, to ensure a successful login, the console user needs to change the

corresponding configuration of the terminal emulation program running on the PC, to make the

configuration consistent with that on the switch. Refer to

Setting Up the Connection to the Console Port

for details.

Advertising