Console port login configuration, Common configuration, Console port login – H3C Technologies H3C S5120 Series Switches User Manual

Page 42: Configuration, Figure

Advertising
background image

2-3

Figure 2-4 Set port parameters terminal window

z

Turn on the switch. The user will be prompted to press the Enter key if the switch successfully

completes POST (power-on self test). The prompt (such as <H3C>) appears after the user presses

the Enter key.

z

You can then configure the switch or check the information about the switch by executing

commands. You can also acquire help by type the ? character. Refer to the following chapters for

information about the commands.

Console Port Login Configuration

Common Configuration

Table 2-2

lists the common configuration of Console port login.

Table 2-2 Common configuration of Console port login

Configuration

Description

Baud rate

Optional

The default baud rate is 9,600 bps.

Check mode

Optional

By default, the check mode of the Console port is set
to “none”, which means no check bit.

Stop bits

Optional

The default stop bits of a Console port is 1.

Data bits

Optional

The default data bits of a Console port is 8.

Console port
configuration

Flow control

Optional

The default is none, which disables flow control.