Table D. Power Cable Termination Requirements

Powerware 9315 SSBM Model: 4000

Terminal Function

Terminal

Function

Number of Cable

Connections per Bus

Tightening

Torque

N-M (lb-ft)

Bolt/Int.

Hex Size

(In.)

AC Input from UPS

SS

E8

Phase A

14 --- 2 bolt mounting

76 (56)

1/2

p

Output to SSBM

E9

Phase B

14 --- 2 bolt mounting

76 (56)

1/2

E10

Phase C 14 --- 2 bolt mounting

76 (56)

1/2

E4

Neutral

24 --- 2 bolt mounting

76 (56)

1/2

Frame

Ground

Ground

30 --- 1 bolt mounting

76 (56)

1/2

AC Input to SSBM

E1

Phase A

12 --- 2 bolt mounting

76 (56)

1/2

p

Bypass

E2

Phase B

12 --- 2 bolt mounting

76 (56)

1/2

E3

Phase C 12 --- 2 bolt mounting

76 (56)

1/2

E4

*Neutral 24 --- 2 bolt mounting

76 (56)

1/2

Frame

Ground

Ground

30 --- 1 bolt mounting

76 (56)

1/2

AC Input to

S

E11

Phase A

14 --- 2 bolt mounting

76 (56)

1/2

p

optional SMB

Bypass

E12

Phase B

14 --- 2 bolt mounting

76 (56)

1/2

Bypass

(Separate Feed)

E13

Phase C 14 --- 2 bolt mounting

76 (56)

1/2

(Separate Feed)

E4

*Neutral 24 --- 2 bolt mounting

76 (56)

1/2

Frame

Ground

Ground

38 --- 1 bolt mounting

76 (56)

1/2

AC Output from

SS

E5 (E15)

Phase A

12 (14) --- 2 bolt mounting

76 (56)

1/2

p

SSBM or Optional

SMB to Critical

E6 (E16)

Phase B

12 (14) --- 2 bolt mounting

76 (56)

1/2

SMB to Critical

Load

E7 (E17)

Phase C 12 (14) --- 2 bolt mounting

76 (56)

1/2

Load

E4

*Neutral 24 (24) --- 2 bolt mounting

76 (56)

1/2

Frame

Ground

Ground

30 (38) --- 1 bolt mounting

76 (56)

1/2

AC Output from

SS

∅ A

Phase A

12 --- 2 bolt mounting

76 (56)

1/2

p

SSBM to Load

Bank

∅ B

Phase B

12 --- 2 bolt mounting

76 (56)

1/2

Bank

∅ C

Phase C 12 --- 2 bolt mounting

76 (56)

1/2

E4

*Neutral 24 --- 2 bolt mounting

76 (56)

1/2

Frame

Ground

Ground

30 --- 1 bolt mounting